194
SV 977D User Manual - Appendixes
Table A.5. Logger parameters
Group name
#1
code
#7
code
#S
code
Code description
Logger
T
0 - Off
1 - On
Summary Results
XXE
0 - Off
1 - On
Logger Meteo
p
0 - Off
1 - On
Logger step
d
n n = number in milliseconds (2, 5, 10, 20,
25, 50, 100, 200, 500, 1000)
ns n = number in seconds (1  60)
nm n = number in minutes (1  60)
Logger Split Mode
XA
0 Off
-1 Sync to the Integration Period
15 Sync. to the full 15 minutes
30 Sync. to the full 30 minutes
60 Sync. to a full hour
1440 Sync. at the Specified Time
Specified Time for Logger
Splitting
XD
n:p n = -1 (switched off)
n = 0..1439 (time in minutes)
p = 1..6 (specified time number)
Logger Name
JT
xxxxx - xxxxx up to 8 characters (permitted
characters: 0-9,A-Z,_)
Summary Statistics Results
MR
0 - Off
1 - On
Summary Meteo Results
MS
0 - Off
1 - On
Summary Spectrum Statistics
Results
MT
0 - Off
1 - On
Summary Spectrum Max
Results
MU
0 - Off
1 - On
Summary Spectrum Min
Results
MV
0 - Off
1 - On
Table A.6. Spectrum parameters
Group name
#1
code
#7
code
#S
code
Code description
Spectrum Band
A
0 - Full
1 - Audio
2 - Ultra
Filter type in 1/x Octave or
FFT analysis in SLM mode
(for Audio band only)
f
1 - Z filter
2 - A filter
3 - C filter
5 - B filter

Table of Contents