Premier Elite Series Installation Manual Engineer Utilities
INS176-15 129
Event Log Descriptions
An exit fault from Zone ### has caused the system to fail to arm
Zone ### has detected a Fault condition
Zone ### has detected a Mask condition
Manual or Periodical Test Call has failed on communication device ###
Zone ### has activated during the walk test
Area have been reset using keypad #,# following an Intruder alarm
The control panel has detected an AC Mains failure
An Open After Alarm-Abort has occurred for area ?
An Intruder alarm signal has been activated for area ?
A reset has been performed using the Anti-code reset procedure
The system has been armed with a Line Fault condition present
A Exit Error-Arm Fail has occurred on area ?
Area Arm Suite # was used to arm the system
The Communicator has failed to report to the Alarm Receiving Centre
There is a problem with the telephone line
An Automatic test call has been initiated
An Auxiliary Tamper input from device #,# has been activated
An Auxiliary Fault input from device #,# has been activated
The Audio Verification unit has been cleared down by user ##
A Bell Tamper input from device #,# has been activated
The Bell output has been activated for area ?
The control panel Bell Fuse has failed
The control panel lid has been removed causing a Tamper alarm
Battery Charge Current has Failed
The internal processor has failed its self checks.
Too many invalid key presses have caused a tamper alarm from keypad #,#
The Com300, 2400 or ISDN has detected a line fault
A com port has generated an alarm
Premier Elite 12.24.48 & 88 Com300/ 2400/ComPort + plugged on incorrectly or the port is programmed incorrectly.
Two or more detectors have activated, resulting in a confirmed alarm condition
Two or more PA zones have activated, resulting in a confirmed PA alarm condition
Two or more detectors have activated, resulting in a confirmed Intruder condition
No event has been stored in memory
A Verified Cross Zone (Beam Pair) Alarm has occurred from zone ###
Programming data has been changed
The control panel Time has been changed
The factory default values have been loaded into memory
The arming mode was deferred for area ?
Door #,# has been opened by a user with Door Control
An Upload/Download has been initiated
The Upload/Download has finished
User ## has entered a Duress Code at a keypad
A reset has been performed using an Engineers code
The Entry mode has been started for area ?
The Exit mode has been started for area ?
A reset has been performed using the input on expander #,# (programmed as reset)
The Input on expander #,# (programmed as line fault) has been activated
Expander ## has been lost from the network
The cover of expander #,# has been removed
Expander #,# has detected that its supply voltage is low
A Panic Alarm from a Radio FOB has been generated
The system has been armed with a Fault condition present by a user
Zone ### (programmed as Fire Alarm) has caused an alarm
Zone ### (programmed as Fire Alarm) has caused an Tamper alarm
Zone ### (which is programmed as double knock) has activated for the first time
The Auxiliary 12V Fuse in device #,# has failed
The GSM Module has lost communications with the control panel
There is a short circuit on iD loop # on the iD expander
A reset has been performed using a key switch
A Keyswitch zone type has been activated (zone number ###)
80% of the Event Log has filled (since the last Upload/Download)
The event log has been erased
The control panel has registered a low battery condition
Expander #,# has detected that’s its supply voltage is low
A Manual test call has been initiated
Microphone ## on the Audio Verification Module has been tested
A zone programmed as key tube has caused an alarm
The Wireless receiver has detected a signal loss from zone ###
A PA has been generated from a Remote Fob
The control panel line fault input has been activated
Area ? has been Part Armed
Part Arm 1 has been selected
Part Arm 2 has been selected
Part Arm 3 has been selected
The panel has opened the programmed port on the router
The panel has not opened the programmed port on the router
System Power Up (without doing a factory restart)
The system has generated a Power Output Fault see Table Power ID Fault on Page 98
The system has generated a rate of voltage failure
The Engineer has logged out of the Programming menu