(8) When the RADF is closed, check if the hole
of the adjustment plate on the right-hand
hinge is aligned with the hole on the
equipment. If it is not, turn the adjustment
screw to match the hole.
Fig. 3-41
(9) Install 1 fixing screw (rear side) on the right-
hand hinge bracket.
Fig. 3-42
(10) Insert a washer, and install 1 fixing screw
(rear side) on the left-hand hinge bracket.
Fig. 3-43
(11) Tighten the 2 fixing screws (front side) on the
hinge bracket.