2
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
SELF-DIAGNOSTIC MODE
2 - 45
202 Copier gamma adjustment pattern
(Color & black / Plain paper 2)
Refer to 3.2.1Automatic gamma adjustment
203 Copier gamma confirmation pattern
(Color / Plain paper 2)
Refer to 3.2.1Automatic gamma adjustment
204 Copier gamma adjustment pattern
(Color & black / Recycled paper)
Refer to 3.2.1Automatic gamma adjustment
205 Copier gamma confirmation pattern
(Color / Recycled paper)
Refer to 3.2.1Automatic gamma adjustment
206 Copier gamma adjustment pattern
(Color & black / Thick paper 1)
Refer to 3.2.1Automatic gamma adjustment
207 Copier gamma confirmation pattern
(Color / Thick paper 1)
Refer to 3.2.1Automatic gamma adjustment
208 Copier gamma adjustment pattern
(Color & black / Thick paper 2)
Refer to 3.2.1Automatic gamma adjustment
209 Copier gamma confirmation pattern
(Color / Thick paper 2)
Refer to 3.2.1Automatic gamma adjustment
210 Copier gamma adjustment pattern
(Color & black / Thick paper 3)
Refer to 3.2.1Automatic gamma adjustment
211 Copier gamma confirmation pattern
(Color / Thick paper 3)
Refer to 3.2.1Automatic gamma adjustment
212 Copier gamma adjustment pattern
(Color & black / Thick paper 4)
Refer to 3.2.1Automatic gamma adjustment
213 Copier gamma confirmation pattern
(Color / Thick paper 4)
Refer to 3.2.1Automatic gamma adjustment
214 Copier gamma adjustment pattern
(Color & black / Special paper 1)
Refer to 3.2.1Automatic gamma adjustment
215 Copier gamma confirmation pattern
(Color / Special paper 1)
Refer to 3.2.1Automatic gamma adjustment
216 Copier gamma adjustment pattern
(Color & black / Special paper 2)
Refer to 3.2.1Automatic gamma adjustment
217 Copier gamma confirmation pattern
(Color / Special paper 2)
Refer to 3.2.1Automatic gamma adjustment
230 Printer gamma correction table creation pattern
(PS: 1200dpi)
(Plain paper 1)
Refer to 3.3.1Automatic gamma adjustment
231 Printer gamma correction table confirmation
pattern (PS: 1200dpi)
(Plain paper 1)
Refer to 3.3.1Automatic gamma adjustment
232 Printer gamma correction table creation pattern
(PS: 1200dpi)
(Plain paper 2)
Refer to 3.3.1Automatic gamma adjustment
233 Printer gamma correction table confirmation
pattern (PS: 1200dpi)
(Plain paper 2)
Refer to 3.3.1Automatic gamma adjustment
234 Printer gamma correction table creation pattern
(PS: 1200dpi)
(Recycled paper)
Refer to 3.3.1Automatic gamma adjustment
235 Printer gamma correction table confirmation
pattern (PS: 1200dpi)
(Recycled paper)
Refer to 3.3.1Automatic gamma adjustment
236 Printer gamma correction table creation pattern
(PS: 1200dpi)
(Thick paper 1)
Refer to 3.3.1Automatic gamma adjustment
237 Printer gamma correction table confirmation
pattern (PS: 1200dpi)
(Thick paper 1)
Refer to 3.3.1Automatic gamma adjustment
Code Types of test pattern Remarks