System
I/O Device
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 4-31
System
I/O Device
Program Number(s): 803, 801 and 804
These commands assign LAN devices, RS-232C devices and device relationships for I/O Logical Devices
SMDR, SMDI, CTI and physical ports.
1. From the Program Menu click
System > I/O Device. The
Equipment Assignment screen
displays (shown right).
2. Enter Program 803 data.
803 SMDR SMDI CTI Port Assignments
This program assigns one of the following:
SMDR and Toshiba Proprietary Integration (TPI) to the logical device and BSIS, RS-232 port numbers.
WinAdmin, ACD server, TPI and Attendant Console to BECU, Network Jack logical device and LAN
port numbers.
FIELD DESCRIPTION
00 Logical Device Number Select the 3 digit logical device number for SMDR, SMDI, and LAN devices or
Network application. See Table 4-5.
Possible values: 100 = SMDR
200~208 = CTI LAN devices or PCs (default = no value)
300 = SMDI of TPI
400 = BLF (for CTX Attendant Console)
500 = DSS (for Telephone, DSS Console, and ADM DSS
buttons)
Note BLF and DSS are available only with CTX Release 1.3 or higher software
and with CTX WinAdmin Release 1.3 or higher software.
01 Device Connection 1. Select RS-232 for SMDR or SMDI devices or PCs. These devices are connected
to BSIS, RS-232 ports.
2. Select LAN for WinAdmin, ACD Server, TPI, and Attendant Console PC. These
devices are connected to the BECU Network Jack directly or via a HUB or LAN.
Possible values: None (default), LAN or RS-232