Station
Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 5-23
Station
Emergency Ringdown Assignment
Program Number(s): 216
Prerequisite Program:
200 page 5-1
Assigns Emergency Ring Down parameters to Primary DNs.
1. Complete the “Station Data
Record Sheets” on
page D-18.
2. From the Program Menu
click Station > Assignment.
3. Click on the RingDown tab
(shown right).
4. Enter a DN number in the
Primary DN field.
...or select an existing record
by clicking one of the
following buttons:
• List – view a summary
list of programmed
DKTs.
• Extended List – view a detailed list of programmed DKTs.
• Copy – Enter a DN in the Primary DN field and click Copy. Enter a new DN to assign existing
Station Timer settings.
5. Select the desired values. See descriptions below.
6. Click Submit
06 Second Interdigit
Timer
Select the amount of time the system waits between dialed digits before terminating a
call (ROT is heard).
Possible values: 1~180 (default = 5)
07 Ring Xfer No
Answer Timer
Select the Ring Transfer Idle station or Busy station (Camp-on) Recall Time (in seconds)
Possible values: 1~600 (default = 32)
FIELD DESCRIPTION
01 Emergency Ringdown Enable an Emergency Ringdown Number.
Possible values: Enable or Disable (default)
02 Emergency Ringdown
Timer
Enter the length of off-hook time that will cause a DN to originate an Emergency
Possible values: 0~60 (default = 0)
03 Destination Enter the destination DN for the Emergency Ringdown.
Possible values: Up to 5 digits (default = no value)
FIELD DESCRIPTION