EasyManua.ls Logo

Toshiba Strata CTX28 - System Programming Error Codes

Toshiba Strata CTX28
592 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Error Codes
System Programming Error Codes
B-2 Strata CTX Programming - Part 4: Appendices 6/04
System Programming Error Codes
Program Code FB
Sub-
parameter
Error Descriptions
100
33
)%
The entered Cabinet/Slot value is out of range.
33
)%
The entered PCB Type is out of range.
33
)%
In CTX100, the Card Type Code other than ASTU (STU) was
assigned into S109.
33
)%
In CTX670, the equipment entered is S109 or S110.
In CTX100, the equipment entered is S110.
49
)%
Deleting a Card (000) – Programmed station and/or trunk
data must be deleted before a card can be deleted.
49
)%
Changing Card Type Code – Card Type cannot be changed.
Delete the existing Card Type before entering a new Card
Type.
49
)%
The designated BIOU is already in use.
49
)%
IOU card cannot be deleted because the Control Relay is
assigned to that card.
49
)%
The PCB cannot be assigned to the designated equipment
position.
49
)%
“004” is not assigned as Card Type Code.
50
)%
One of the required parameters (PCM Highway, BDKU Type
or TEI Assignment) has not been assigned.
50
)%
The PCM highway value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
50
)%
The Channel Type value entered is not applicable for the
desired PCB assignment. PCB parameters are required for
PDKU or BDKU, RDTU, RDSU, RPTU.
50
)%
The TEI Type value entered is not applicable for the desired
PCB assignment. PCB parameters are required for PDKU or
BDKU, RDTU, RDSU, RPTU.
54
)%
The number of MF2U cards exceeds the system limit.
102
33
)%
The entered Feature Code is out of range.
33
)%
The OLG entered is out of range.
49
)%
An invalid OLG number was entered in OLG Number field
when assigning a Flexible Numbering Feature code of 551.
50
)%
“0” is not a valid OLG Number.
51
)%
Flexible Numbering Plan values cannot be repeated. The
value entered cannot be registered (e.g., If 1234 is registered,
123 cannot be registered).
52
)%
The value entered conflicts with an existing extension and
cannot be registered.
103 -
See Common Error Code Table” on page B-1.