Trunks
300 Trunk Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 6-11
Trunks
310 DIT Assignment
Prerequisite Program: 300 page 6-6
This program assigns DIT Number Analysis Table for DIT trunks. DIT trunks are ground and loop start
trunks.
1. Complete the “Trunk Timer/DIT
Record Sheet” on page D-27.
2. From the Program Menu, click
Trunk > Assignment, then click the
DIT tab. The DIT Assignments
screen displays (shown right).
3. Enter Trunk equipment number
field. Enter Program 310 data.
•List to view a summary list of
programmed Trunks timers.
Copy – to copy to trunk timer
ports.
4. Click Submit.
04 Pause after Flash Pause time after flash: After a flash signal is sent to a CO line, this timer determines
when the line will start to send the dialed digits to the other end.
Possible values: 0~5, 0 = immediately sent, and 1sec.delay to 5sec.delay
(default = 1 second delay before sending digits)
05 Response
Information
The response timer is for analog DID/TIE lines that have the “start method” set for
“Timing” in Prg300-06. After a line is seized this timer determines when the line will start
to send the dialed digits to the other end.
Possible values: 0=immediatly sent, and 50msec.delay to 500msec.delay
(default = 500mseconds delay before sending digits)
06 Call Abandon Timer The interval after which the CTX stops sending ring tone to stations when an incoming
call is abanboned (caller hangs up before the call is answered).
FIELD DESCRIPTION