EasyManua.ls Logo

Toshiba Strata CTX28 - Trunk Timer

Toshiba Strata CTX28
592 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trunks
300 Trunk Assignment
6-10 Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
308 Trunk Timer
Prerequisite Program: 300 page 6-6
These commands assign Trunk timers.
1. Complete the “Trunk Timer/DIT
Record Sheet” on page D-27.
2. From the Program Menu, click
Trunk > Assignment, then click the
Timer tab. The Trunk Timer and
DIT Assignments screen displays
(shown right).
3. Enter Trunk equipment number
field. Enter Program 308 data.
•List to view a summary list of
programmed Trunks timers.
Copy – to copy to trunk timer
ports.
4. Click Submit.
FIELD DESCRIPTION
Line No. Enter the trunk equipment number.
Possible values: xx = Cabinet 01~07; yy = Slot 01~10; zz = Circuit 01~08 or
zz = T1 Circuit 01~24 (CTX670)
xx = Cabinet 01; yy = Slot 01~08; zz = Circuit 01~24 (CTX100)
(default = no value)
Note Equipment numbers are required when assigning a new trunk to the system. It
can also be used to display the equipment location of existing trunks.
01 Auto Release Select the Automatic Release timing.
Possible values: Disable, Detect 95ms or Detect 450ms (default)
Note Select Disable if the CO does not send the automatic release signal to the loop
start trunk.
02 Short Flash Select Short Flash Time
Possible values: 0~15, where 1 = 100msec. (default = 5, which is .5 seconds)
0 = no flash, 1 = .1 sec., 2 = .2 sec. – 15=1.5 sec. 5 is the most
common duration of a hook flash signal
When a telephone initiates the short flash signal to the CO line it is connected to (using
the short Flash feature button or access code #450) the duration of a short flash is
determined by this command. Normally this signal is used to hook flash a centrex line.
The short flash range is 0 to 1.5 seconds in increments of 0.1 seconds.
03 Long Flash Select Long Flash Time.
Possible values: 0, 5, 10, 15, 20, 25 and 30, where 5 = .5 seconds. (default = 5)
When a telephone initiates the long flash signal to the CO line it is connected to (using
the Long Flash feature button or access code #451) the duration of a long flash is
determined by this command. Normally this signal is used to disconnect the line. The
long flash range is 0 to 3 seconds in increments of 0.5 seconds. Possible values: 0=no
flash, 5=.5 sec., 10=1sec. 15=1.5 sec., 20=2 sec., 25=2.5 sec., 30=3 sec.

Table of Contents

Other manuals for Toshiba Strata CTX28

Related product manuals