Services
Network Busy Lamp Field (BLF) (R1.3 and higher)
9-48 Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
Network DSS/BLF for Digital Telephones
System Availability: Not available with CTX28
Follow these steps to program Network BLF/DSS and Figure 9-2:
Figure 9-2 Network BLF Example
Important! See steps for programming Network BLF from CTX WinAdmin on the following pages
Remote
(CTX100)
Program 916 - Set
IP Address = 192.168.16.44
Program 803 - Log. Device
= 400 (BLF), Port 11
Progra 801 - BLF Server
Port = 6000
Program 670 - Assign
Remote Nodes Data
Program 916 - Set IP
Address = 192.168.17.43
Program 803 - Log. Device
= 400 (BLF), Port 11
Program 801 - BLF Server
Port = 6000
Program 670 - Assign
Primary & Remote Node
Data CTX100
Program 916 - Set IP
Address = 192.168.18.53
Program 803 - Log. Device
= 400 (BLF), Port 11
Program 801 - BLF Server
Port = 6000
Program 670 - Assign
Primary & Remote Node
Data CTX670
QSIG
QSIG
Primary
(CTX670-1)
Remote
(CTX670-2)
6877
LAN / Switch / Hub LAN / Switch / Hub LAN / Switch / Hub
IP-NetworkIP-Network
Program 656
Node ID: 16
Program 656
Node ID: 17
Program 656
Node ID: 18