Services
Network Busy Lamp Field (BLF) (R1.3 and higher)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 9-49
Services
¥
Programming Network BLF from WinAdmin for Digital Telephones
System Availability: Not available with CTX28
Perform the all of the following steps on the local CTX first, then repeat them on each of the remote CTXs.
1. Create the Node ID in “102 Flexible Access Codes” on page 4-4.
Note If you have already created the Node ID using QSIG, skip Step 1 and go to the next step.
2. Set up the IP address of the primary CTX using Program “916 IP Configuration” on page 10-14.
3. From the Program menu, select Services > Networking > Node ID to set the Primary Node ID. Refer to
“656 Node ID Assignment” on page 9-54.
4. From the Program menu, select System > I/O Device. Refer to Program “803 SMDR SMDI CTI Port
Assignments” on page 4-31.
00 Logical Device No. = 400 (BLF)
01 Device Connection = LAN
02 Device Port No. = 11
5. Define the LAN Device port number (11 in the example above). Select System > I/O Device, select the
LAN Device tab. Refer to 801 Network Jack LAN Device Assignment” on page 4-33. Make the
following selections:
00 LAN Port No. = 11
01 Protocol = TCP
02 PC Operation Type = Server
03 Data Flow = Asynchronization
04 Server Port No. = 6000
05~08 Client IP 1-4 No. = Default
09 Client Port No. = Default
10 Read Retry No. = 1
11 Write Retry No. = 1
6. Verify the DSS refresh time in System > System Timer, FB 23 – System Timer Network DSS Refresh
Timer. Refer to “104 System Timer” on page 4-11.
7. From each remote CTX, repeat steps 1~6 to set up Network BLF.