Telephone Button Programming
100 Series Programs
Strata CTX Programming - Part 3: Telephone Button Programming 6/04 13-11
Telephone Button
Programming
100 Series Programs
Table 13-1 Program 100
Button Sequence Value(s) Summary
100
Card Slot Assignment
,
+ROG
100-00 Card Slot Assignment
xxyy,
+ROG
xx =
yy =
Cabinet: 01~02 (Basic
CTX670 and CTX100)
01~07 Expanded CTX670
Slot: 01~8 (CTX100)
01-10 (CTX670)
Equipment Number
100-01
PCB Type
)%
, nnn,
+ROG
,
+ROG
nnn = 3 digit PCB Code (See
table below). Valid Codes:
000, 001, 002, 005, 006,
009, 010, 011, 013.
Assign one of the following:
• BIOU1 or BIOU2 Page/MOH/BGM Relay Control.
• RSTU or PSTU w/ 8 standard phones.
• All Analog CO Line OCBs.
• BVPU with 4 VoIP circuits.
• RBSU/RBSS with 4 BRI S/T interface.
• Delete PCB
100-02 PDKU/RDTU/RPTU
Options
)%
, nnn,
+ROG
,
)%
, n,
+ROG
,
+ROG
nnn =
n =
3 digit PCB Code. Valid
Codes: 017, 018
1. None
2. DKT no OCA or 8 Ch
3. DKT w/ OCA or 16 Ch
4. 24 Ch (n/a for PDKU)
5. 30 Ch (n/a for PDKU)
Assign one of the following:
• PDKU with OCA toggle
• RDTU or RPTU, T1 or PRI Channel
100-03 BDKU/BDKA Options
)%
, nnn,
+ROG
,
)%
, n,
+ROG
,
+ROG
nnn =
n =
3 digit PCB Code Valid
Codes: 003, 007, 014
1. None
2. 8 DKT no OCA
3. 8 DKT w/ OCA
4. 16 DKT no OCA
5. 16 DKT w/ OCA
Assign BDKU or BDKS
100-04 BRI TEI Options
)%
, nnn,
+ROG
,
)%
, n,
+ROG
,
+ROG
nnn =
n =
3 digit PCB Code. Valid
Codes: 012, 013, 015, 016
1. None
2. 8 DKT no OCA
3. 8 DKT w/ OCA
4. 16 DKT no OCA
5. 16 DKT w/ OCA
Assign RBUU/RBUS or RBSU/RBSS.