Services
Network Busy Lamp Field (BLF) (R1.3 and higher)
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 9-51
Services
¥
Program Network DSS from WinAdmin
System Availability: Not available with CTX28
1. Create the Node ID in “102 Flexible Access Codes” on page 4-4.
Note If you have already created the Node ID using QSIG, skip Step 1 and go to the next step.
2. Set up the IP address of the primary CTX using Program “916 IP Configuration” on page 10-14.
3. From the Program menu, select Services > Networking > Node ID to set the Primary Node ID. Refer to
“656 Node ID Assignment” on page 9-54.
4. Program the CTI Port for Network DSS. From the Program menu, select System > I/O Device. Refer to
“803 SMDR SMDI CTI Port Assignments” on page 4-31.
00 Logical Device No. = 500 (DSS)
01 Device Connection = LAN
02 Device Port No. = 12
5. Define the LAN Device port number (12 in the example above). Select System > I/O Device, select the
LAN Device tab. Refer to 801 Network Jack LAN Device Assignment” on page 4-33. Make the
following selections:
00 LAN Port No. = 12
01 Protocol = UDP
02 PC Operation Type = Server
03 Data Flow = Asynchronization
04 Server Port No. = 3000
05~08 Client IP 1-4 No. = Default
09 Client Port No. = Default
10 Read Retry No. = 1
11 Write Retry No. = 1
Select FB01 Protocol to UDP and FB04 Server Port No. to 3000. FB04 is the DSS Server Port. All
other parameter can have defaults.
6. Make sure the Remote Node IP address and Network DSS port Number are consistent. From the
Program Menu, select Services > Networking > Remote Node Data Assignment (Program 670).
7. In Program 670, enter the parameters as follows:
Remote Node ID = 17. (This is a QSIG Node ID. In the example above these Node IDs are 16, 17
and 18.
Remote Node IP Address = IP address of the remote CTX. Using Node 17 in this example, the IP
address is 192.168.1.43.
Remote Node Port No. = 3000. This port number is the Network DSS port number. The Network DSS
port number can be any available port. All Network DSS ports should also be the same, i.e; 3000 in the
above example.
8. Verify the DSS refresh time in System > System Timer, FB 23 – System Timer Network DSS Refresh
Timer. Refer to “104 System Timer” on page 4-11.
9. Assign the DSS Remote Node feature key using Program 205, 213 and 215. Refer to “Key” on
page 5-16. DSS button can have up to seven digits, so Node ID can be included. Before R1.3 five digits
were the maximum allowed in a DSS button.
10. From each remote CTX, repeat steps 1~9 to set up Network DSS.