Operation
911 Remote Program Update
10-12 Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04
Important!
O
If power is turned off/on or if the Strata CTX is re-started before switching the Active software from
“Trial” to “Normal”, the CTX670 will switch the old software back to Active.
O
It is your responsibility to verify the system is working correctly after Remote Update is complete.
Notes
O
If the new version of software is not performing properly, on the CTX670 only, you can activate
the old version of software again by initiating a Clear-reboot.
O
Clear-reboot swaps the active and standby sides of flash memory. You must always install a
SmartMedia card containing a copy of the current back up data before initiating a Clear-reboot or
all programmed data will be erased.
O
If the CTX100 system is not working properly with the new software, you must reinstall the
original software using this Update procedure.
Table 10-1 Program Update Screen Field Descriptions
FIELD DESCRIPTION
Upload from Folder Select the Strata CTX type.
Possible values: CTX100_R_MXnnn, CTX670_R_MXnnn.
Version Number Software version number displays. Example: A102MXnnn00. See CTX Software
Identification.
Number of Files Displays number of files that have to be uploaded. This file is static.
Files Uploaded Displays number of files uploaded. This is a dynamic field and will change during
the process.
Operation
Completion
View operation status.
Copied blocks View number of blocks copied.
Possible values: 0~65536 (default = 0)
Total Blocks View total blocks to be updated.
Possible values: 0~65536 (default = 0)
Active Side ID Active Side Number.
Possible values: 0 or 1 (default = 0)
Active Side Status Software status display.
Possible values: Normal (default), Trial, Fault, Don’t care or Error
Standby Side Status Standby Backup Type. This field will display only when connected to a CTX670. It
will not display when connected to CTX100.
Possible values: Normal (default), Trial, Fault, Don’t Care or Error