System
105 System Data
Strata CTX Programming - Part 2: CTX WinAdmin Programming 6/04 4-15
System
16 Multi-Conference Enable Multi-Conference capabilities for Analog Internal Calls and Outgoing Calls.
Possible values: Enable or Disable (default)
17 Caller Number Display Enable Caller Number Display. If a soft key display competes with a Caller ID, the
Caller ID displays.
Possible values: Enable (default) or Disable
18 Night Bell Relay Assign BIOU Relay as the Night Bell Relay; this relay activates whenever Night
Ringing takes place.
Possible values: 0~8 (default = 0)
BIUO1 provides relays 1 to 4; BIUO2 provides relays 5 to 8
Note On CTX100 the ACTU built-in relay is programmed as relay 5. For this
operation, in Program 100 the BIOU2 must be installed in Cabinet 2 Slot 5,
PCB code 20.
19 Display Preference Select Display Preference.
Possible values: DNIS (default) or Caller ID
20 Transit Counter Select the Networking Transit Counter. This device limits the number of nodes
through which a QSIG call can pass before being terminated as a lost call.
Possible values: 0~128 (default = 1)
21 Primary Clock
22 Secondary Clock
Enter data as xxyyzz.
zz=channel 01 if clock source is RPTU or RDTU
zz=channel 01, 02, 03, or 04 if clock source is RBUU/RBUS or RBSU
Example: If the Primary Clock Source should be a assigned to an RPTU in cabinet
5, slot 2, enter 050201.
Cabinet numbers:
CTX100: Select 01 for Base and Expansion cabinet.
CTX670: Select 01 for Base and 02~07 respectively for each Expansion cabinet.
Slot numbers:
CTX100: Select 01~04 for Base slots and 05~08 for Expansion slots.
CTX670: Select 01~08 for Base slots and 01~10 for Expansion slots.
23 Call History Prefix 1 Add the dialing prefix 1 when using the callback feature in Call History.
Possible values: Add (default) or Do Not Add
24 Emergency Digits Sent Enter an alternative emergency dialing string. If no value is entered in this field any
previously programmed value is overwritten.
Possible values: Up to 5 digits (default = 911)
25 DP Make Ratio Select the Dial Pulse Make/Break ratio.
Possible values: 33% (default) or 40%