Standards
and
lEC
Classifications
The
CUSA
EXcel
is
intended
for
use
in
the
electromagnetic
environment
specified
below. The
customer
or
the
user
of
the
CUSA
EXcel
should
assure
that
it
is
used
in
such
an
environment.
Immunity
test
TEC
60601
test
level
Compliance
level
Electromagnetic
environment
-
guidance
Portable
and
mobile
RF
communications
equipment
should
be
used
no
claser
to
any
part
of
the
CUSA
EXcel,
including
cables,
than
the
recommended
separation
distance
calculated
from
the
equation
applicable
to
the
frequency
of
the
transmitter.
Recommended
separation
distance
Conducted
RF
3
Vrms
3V
d=1/2VP
IEC
61000-4-6
150KHz
to
80MHz
Radiated
RF
IEC
3
V/m
7
V/m
d=0.5VP
80MHz
to
800MHz
61000-4-3
80MHz
to
2.5GHz
d=VP
800MHz
to
2.5GHz
Where
P
is
the
maximum
output
power
rating
of
the
transmitter
in
watts
(W)
according
to
the
transmitter
manufacturer
and
d
is
the
recommended
separation
distance
in
meters
(m).
Field
strengths
from
fixed
RF
transmitters,
as
determined
by an
electromagnetic
site
survey,
should
be
lass
than
the
compliance
level
in
each
frequency
range
Interference
may
occur
in
the
vicinity
of
equipment
marked
with
the
following
symbol:
O)
NOTE
1
At
a80MHz
and
800MHz,
the
higher
frequency
range
applies.
NOTE
2
These
guidelines
may
not
apply
in
all
situations.
Electromagnetic
propagation
is
affected
by
absorption
and
reflection
from
structures,
objects
and
people.
a.
Field
strengths
from
fixed
transmitters,
such
as
base
stations
for
radio
(cellular/cordless)
telephones
and
land
mobile
radios,
amateur
radio,
AM
and
FM
radio
broadcast
and
TV
broadcast
cannot
be
predicted
theoretically
with
accuracy.
To
assess
the
electromagnetic
environment
due
to
fixed
RF
transmitters,
an
electromagnetic
site
survey
should
be
considered.
If
the
measured
field
strength
in
the
location
in
which
the
CUSA
EXcel
is
used
exceeds
the
applicable
RF
compliance
level
above,
the
CUSA
EXcel
should
be
observed
to
verify
normal
operation.
If
abnormal
performance
is
observed,
additional
measures
may
be
necessary,
such
as
reorienting
or
relocating
the
CUSA
EXcel.
b.
Over
the
frequency
range
150kHz
to
80MHz,
field
strengths
should
be
less
than
3
V/m.
-一
The
CUSA
EXcel
is
intended
for
use
in
the
electromagnetic
environment
specified
below.
The
customer
or
the
user
of
the
CUSA
EXcel
should assure
that
it
is
used
in
such
an
environment.
5-10
CUSA
EXcel-8
System
Service
Man

Table of Contents

Related product manuals