This manual shows only the parameters that have an operational relevance to the ICON32. The UIT may have
additional parameters available, which should not effect the controller operation.
D14 0.1 sec. 0–100
Safety Edge Door Time - This adjustment sets the length of time the doors will stay open
after the safety edge is activated.
D15 0.1 sec. 4–50
Electric Eye Door Time - This adjustment sets the length of time the doors will stay open
after the electric eye is activated.
D16 0.1 sec. 0–100
Door Open Button Door Time - This adjustment sets the length of time the doors will stay
open after the door open push button activation.
D17 sec. 5–900
Door Hold Button Door Time - This adjustment sets the length of time the doors will stay
open after the door hold push button activation.
D18 0.1 sec. 0–40
Open High Speed Time - This adjustment sets the amount of time delay after the doors
start the opening cycle with OD and before picking the OHS Relay.
D19 sec. 5-120
Nudging Door Time - This adjustment sets the length of time that the door must be held
open before nudging is activated. See also: D11, D40, F23, Z16.
D20 0.1 sec. 0–60
Door Reversal Time (optional) - If the electric eye remains active, this
adjustment is the length of time the doors will remain at the door reversal limit (DRL) switch
before fully opening.
Note: To enable this feature, the limited door reversal type must be non-zero.
See also: D10
D21 0.1 sec. 0–600
Front Door Watchdog Time - If the doors do not reach the door close limit before this timer
expires, the system assumes the doors have failed. The doors will be reopened and
another close cycle attempted.
D22 0.1 sec. 0–600
Rear Door Watchdog Time - If the doors do not reach the door close limit before this timer
expires, the system assumes the doors have failed. The doors will then be reopened and
another close cycle attempted.
D23 0.1 sec. 50–300
ADA Hall Call Door Time - This adjustment sets the length of time the doors stay open
when answering hall calls with the ADA option enabled.
D24 0.1 sec. 1–300
Car Call Door Time - This adjustment sets the length of time the doors stay open when
answering car calls under normal operation.
D25 0.1 sec. 1–300
Hall Call Door Time - This adjustment sets the length of time the doors stay open when
answering hall calls under normal operation.
D26 0–2
Door Disconnect.
Values:
0 = The door disconnect feature is deactivated.
1 = The door disconnect feature is active.
2 = Capture the car on door disconnect.
Note:
"3" is not a user setting. D26 = 3 followed by WRT will reload the job configuration
file in order to recover elevator operation.
D27 0–1 ADA - Set to
"1" to meet ADA legal requirements (USA).
D28 sec. 30–600
Stuck Device Time - This adjustment sets the length of time a door opening device (such
as the Door Open Button) must be active before it is recognized as being stuck.
D29 0–1 Extended Door Time Enable - To activate this feature, set adjustment D30.
D30 0.1 sec. 10–250
Extended Door Time - This adjustment sets the length of time added to the standard door
time when the car is at the Extended Door Time Landing.
D31 floor 1–nf Extended Door Time Landing.
D34 0–1
Non-simultaneous Door Enable.
Values:
0 = Disable non-simultaneous doors
1 = Enable non-simultaneous doors
D38 sec. 3–120
Sabbath Door Hold Time - The time (in seconds) the doors will hold open at each floor
when the car is operating on Sabbath Operation.
Adj (cont.) Unit Range Definition (cont.)