ALPHA/DELTA INSTALLATION & MAINTENANCE CHECKLIST
ALPHA/DELTA INSTALLATION AND MAINTENANCE
CHECKLIST
Checked Good Needs
Aenon
N/A
29� Conduits
All conduits must be nished to the applicable
electrical code(s) into the boom of the operator
cabinet only. This will help to prevent water entry
into the operator cabinet and will allow for proper
installaon of thermal cover (if required).
30� Motor Brushes
Check motor brushes for wear. Brushes should be
replaced every 2 years.
31� Thermal Cover/Thermostat
If supplied as part of the installaon, ensure the
thermal cover ts appropriately over the cabinet
and Velcro straps are appropriately fastened.
Installaon/removal of cover should be clearly
understood by end user. Thermostat is self-
regulang at 40.1°F (4.5°C).
Comments/Recommendaons:
Customer Signature: Customer Name (Print):
Signature of Maintenance Inspector: Maintenance Check Performed by (Print Name):
Date:
Date of next Maintenance Inspecon:
Cycle Count: