Fold the module away from the standard rail and remove it from the rail.
Step 2: Removing gateways and expansion modules
Deenergize the samosPRO system.
Remove plug-in terminals with wiring and remove the end terminals.
Pull the modules apart from one another individually in the direction of the arrow until the
lateral plug connection is disconnected.
Press on the module from above and fold the module away from the standard rail while it
is in the pressed-down state.