6. Cylinder Lubricating System Bleed
To bleed the lubrication oil supply pipe (10, Fig. 4), and the cylinder lubricating pumps,
see the procedure given in the Maintenance Manual 72181.
After you bleed the lubricating oil supply pipe (10), and the cylinder lubricating
pumps (see paragraph 5.3), it is necessary to bleed the oil pipes (4) to the lubricating
quills (5) as follows:
1) See 4002-2, LDU-20, paragraph 3.2 User Guide and paragraph 3.9 Cylinder
Lubrication.
2) In the LDU-20, get the MAIN page.
3) In the navigation menu, select Cylinder Lubrication.
4) In the CYL. LUBRICATION page, field Manual lub. to Cyl. #, select the applicable
cylinder number.
Note: If necessary, it is possible to change the number of lube pulses (in the
range 0 to 200) in the field # of Manual Lub. Pulses.
When 100 is entered in the field Manual lub. to Cyl. #, all cylinders will be
lubricated in sequence.
5) Do the procedure given in the Maintenance Manual 72181.
2015-03