EasyManua.ls Logo

WinGD X72 - Particle Size and Count

WinGD X72
514 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation07501/A1
Winterthur Gas & Diesel Ltd.
4/ 18
If the system oil is used for more than one year, the FZG performance of the oil must
be done to make sure that the performance is sufficient for the new or polished
gear(s).
You must do regular on-board checks of the BN and water content to get an early
indication of a lower oil quality.
2.3 Particle Size and Count
Particle size analysis can give useful data about the wear in an engine. Abrasive
particles in the oil can cause wear, thus the procedures must be carefully followed.
The hydraulic system operates the exhaust valve and the fuel and cylinder lubricating
oil injection systems.
The ISO 4406 particle count and size classes are applicable for the system oil
downstream of the filter and given in Table 3.
201611
Lubricating Oils

Table of Contents

Other manuals for WinGD X72

Related product manuals