3. Engine Local Control
You can operate the engine from the local control panel (see 40022, Local Control
Panel/ Local Display Unit (LDU-20).
The speed controller is part of the ECS. If the MCM-11 becomes defective, the fuel
command mode is selected automatically.
Note: The operator must not leave the local maneuvering stand. The operator
must regularly monitor the engine speed so that the fuel supply can be
immediately adjusted when necessary.
3.1 Preparation
1) On the LDU-20, select the CTRL. TR. button. The CONTROL LOC page shows
(see 40022 Local Control Panel/Local Display Unit LDU-20, paragraph 3.4).
2) Select the Local button for mode transfer to local manual control.
3) Push the rotary button to go back to the MAIN page.
3.2 Engine Start
1) On the LDU-20, select the button ON/OFF to start the auxiliary blowers.
2) Use the rotary button to select the Fuel Command mode.
3) Turn the rotary button to set the manual fuel command setpoint to
approximately 15%.
4) Select the button START AHD or START AST until the engine operates.
5) Turn slowly the rotary button to adjust the fuel injection quantity until the engine
operates at the applicable speed. You can see the related value on the display
and speed indicator.
Note: You can also use the the LDU-20 on the ECR control panel for the engine
start procedure. But the buttons and rotary button operate only when the
related LDU20 has control (see 40022 Local Control Panel/ Local
Display Unit (LDU20), paragraph 3.4).
3.3 Reverse
1) On the LDU-20, turn the rotary button to set the manual fuel command setpoint to
approximately 15%.
2) Select the button START AHD or START AST until the engine operates in the
correct direction.
Note: On ships under way, this procedure can be a long period because of
propeller drag.
3.4 Engine Stop
1) Turn the rotary button to decrease the engine speed/load.
2) Push the STOP button.
For more data about engine stop, see 03101 Engine Shutdown.