2014 Operation Manual, Issue 2014
x
Date of publication 2014-07-16
0250-1/A1 2014-08
Operating Data Sheet
Minimum value for vibration damper changed from 1.5bar
to 1.0bar
x
0250-2/A1
E-Mail Beat
Schumacher
21. Apr 2014
Alarms and Safeguards
Changed the alarm level value for pressure transmitter
PT2711A from 1.0 bar to 1.5 bar (Geislinger damper)
x
0710-1/A1
Operating Media - Diesel
Engine Fuels
Chapter updated with latest data (English and minor
changes)
x
8016-1/A1
Service
Bulletin
RT-138
Lubrication Oil System Paragraph 2.1: procedure updated (see RT-138) x
Date of publication 2014-08-19
OM_2015-03 2015-03
Cover Page and
Disclaimer
New Layout WinGD;
Disclaimer updated (WinGD and WSCH added);
x
0000-1/A1
2015-03
For Your Attention Data updated (WinGD and WSCH added); x
0010-1/A1 2015-03 Preface
Minor text changes; Data about Wärtsilä Service
Switzerland Ltd added;
x
0020-1/A1 2015-03 Table of Contents New chapter 4605-1/A2 added x
0030-1/A1 2015-03 Subject Index New chapter 4605-1/A2 added x
0035-1/A1 2015-03 Abbreviations New entries added x
0110-1/A1 2015-03
Prepare for Engine Start
after a Short Shut-down
Period
page 1: Cooling Water inlet temperature changed from
60°C to 65°C (ALM L value TE1111A = 65°C);
page 2: Reference to 0210-1 added (Warning);
x
0210/1-A1 2015-03
Safety Precautions and
Warnings (General Data)
paragraph 2: Warning about oil mist detector added;
paragraph 8: Warning about hot parts added;
paragraph 9: Warning about injury hazards added;
paragraph 13: Warning about air run added;
x
0220-1/A1 2015-03
Input Product
Manager
Operation during Usual
Conditions - Slow Turning
para 2: Warning added; x
0250-1/A1 2015-03
EAAD085793
EAAD085660
E-Mail Beat
Schumacher
21. Apr 2014
Operating Data Sheet
Values for fresh water cylinder cooling (inlet) changed from
min. 4.5 bar to 4.0 bar and max. from 5.5 to 5.0 bar;
Data about thrust bearing removed;
New data about high/low pressure lubricating oil system
added;
Document structure changed;
Minimum value for vibration damper changed from 1.0bar
to 1.5bar (related to ALM value PT2711A);
x
0250-2/A1 2015-03
Input from
Bruno Frei
12/2015, E-
Mail from
licensee; new
data for
engines rated
with CMCR
speed less
than or equal
to 75 rpm;
EAAD085793
Operating Data Sheet
PT2003A remark 'before injectors' added;
Name of TE2011A (Crank Pin Bearing Oil, optional)
changed to TE2201-08A;
TE2101-10A (Outlet Bearing 1 to 10, optional) added;
TE2501-08A and FS2521-28S moved to section
'Lubricating Oil - Bearings';
PT2021A (booster pump inlet) added;
TE2301-08A (crosshead bearing oil outlet, optional) added;
PT1101A ALM changed to 4.0 bar, SLD changed to 3.8
bar;
PS1101S SHD changed to 3.5 bar;
x
Manual
Modification Service
X72
Modification
Page or

Table of Contents

Other manuals for WinGD X72

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WinGD X72 and is the answer not in the manual?

WinGD X72 Specifications

General IconGeneral
BrandWinGD
ModelX72
CategoryEngine
LanguageEnglish

Related product manuals