1/ 11
Servo Oil Rail
Exhaust Valve Control Unit Pilot valve : Removal and Instal-
lation
1. General 1..........................................................
2. Preparation 1.......................................................
3. Removal and Installation 2..........................................
4. Completion 2.......................................................
1. General
The pilot valve for each VCU for cylinder can be replaced individually.
2. Preparation
1) Stop the engine, refer to 03101.
2) Release the pressure in the servo oil rail, refer the Operation Manual 05201 para-
graph 2.3.
3) Remove the applicable hydraulic pipe, refer to 84601, paragraph 1 and para-
graph 2.