Phaser 6121MFP Service Manual 3-11
Error Messages and Codes
0052 Phase 4 signal not received within 20 seconds after phase 3 in V.34.
0053 Modem disconnect after phase 4 in V.34.
0054 Remote side disconnected after phase 4 in V.8.
0055 Received incorrect signal after sending DIS signal in V.34.
0056 Modem disconnect after sending CFR in V.34.
0057 Image signal not detected within 6 seconds after sending CFR.
0058 Image signal not detected within 6 seconds after modem enter to 
primary phase in V.34.
005A Modem can not detect a correct ECM frame with 3 minutes in phase C.
005B Cannot detect phase 5 signal within 6 seconds after primary channel.
005C Detect busy tone within control channel after phase C.
005D Modem can not detect any correct ECM frame with 12 seconds in phase 
C.
005E Control channel signal not detected within 6 seconds after receiving RCP 
frame.
005F Silence not detected after sending JM signal for polling TX function.
0060 There are no bulletin files to be polled in V.34.
0061 V.21 or V.8 signal not detected within 35 seconds.
0062 Modem disconnect in phase D after sending out flags sequence in 
control channel.
0063 Flag sequence not received in control channel within 6 seconds in 
phase D.
0064 Control channel signal not detected in phase D within 60 seconds even 
though energy still on the line.
0065 Control channel signal not detected within 60 seconds after detect 
silence in phase D.
0066 T.30 signal or carrier not received after sending CFR in V.34.
0070 User pressed stop key when receiving.
0071 Memory full when receiving.
0072 Received EOR_Q Signal.
Code Description