Problem Solving for the Interface Module
/ Interface Cooling Module
Fault Codes - Interface Module / Interface Cooling Module
Recommended SolutionPossible CauseFault Code
1. Open the Module front
door.
2. Remove all sheets or
pieces from the jam clear-
ance areas.
3. Close the front door.
4. Verify that the paper be-
ing used is within specifica-
tions.
Paper Jam during feeding048-100 to 048-107
Ensure door is fully closed.Module front door is open048-300
1. Power Off / On the press.
2. If error persists, contact
the Customer Support
Center.
Decurler Sensor or Belt issue048-310, 048-311, 048-
312, 048-313, 048-314,
048-315, 048-316
1. Power Off / On the press.
2. If error persists, contact
the Customer Support
Center.
Cooling fan failure048-317, 048-318, 048-
319
1. Ensure all jams are cleared.
2. Ensure all handles / levers
are returned to closed pos-
ition.
3. Power Off / On the press.
4. If error persists, contact
the Customer Support
Center.
Communication failure or connec-
tion failure
048-320 to 048-324
20-5Xerox
®
Versant
®
80 Press
User Guide
Interface Module / Interface Cooling Module