13 Troubleshooting
13.3.2 Motion Error Details and Corrections
13-32
(18) Monitoring Status (IW2C)
The status of the
SERVOPACK can be monitored in the bits of monitoring parameter
IW2C
.
Bit No. Status Description
Bit 0 Alarm (ALARM) OFF: No alarm occurred.
ON: Alarm occurred.
Bit 1 Warning (WARNG) OFF: No warning occurred.
ON: Warning occurred.
Bit 2 Command Ready (CMDRDY) OFF: Command cannot be received.
ON: Command can be received.
Bit 3 Servo ON (SVON) OFF: Servo OFF.
ON: Servo ON.
Bit 4 Main Power ON (PON) OFF: Main power OFF.
ON: Main power ON.
Bit 5
Machine Lock (MLOCK)
OFF: Machine lock mode released.
ON: Machine lock mode.
Bit 6
Zero Point Position (ZPOINT)
OFF: Not in Zero Point Position Range
ON: In Zero Point Position Range
Bit 7
Positioning Completed (PSET)
OFF: Pulse distribution not completed or not in Positioning Completed
Width.
ON: Pulse distribution completed and in Positioning Completed Width.
Bit 8 Distribution Completed (DEN) OFF: Distributing positioning pulses.
ON: Pulse distribution completed for positioning.
Bit 9 Torque Being Limited (T_LIM) OFF: Torque not being limited.
ON: Torque being limited.
Bit A Latch Completed (L_CMP) OFF: Latch not completed.
ON: Latch completed.
Bit B Position Proximity (NEAR) OFF: APOS is outside Position Proximity Range.
ON: APOS is inside Position Proximity Range.
Bit C
Positive Soft Limit (P-SOT)
OFF: Not in Positive Soft Limit Range.
ON: In Positive Soft Limit Range.
Bit D
Negative Soft Limit (N-SOT)
OFF: Not in Negative Soft Limit Range.
ON: In Negative Soft Limit Range.
Bit E Reserved.
Bit F Reserved.