No. Name
User
Setting
d3-04 Jump Frequency Width
d4-01 Frequency Reference Hold Function Selection
d4-03
Frequency Reference Bias Step (Up/Down 2)
d4-04
Frequency Reference Bias Accel/Decel (Up/Down
2)
d4-05
Frequency Reference Bias Operation Mode
Selection (Up/Down 2)
d4-06 Frequency Reference Bias (Up/Down 2)
d4-07
Analog Frequency Reference Fluctuation Limit
(Up/Down 2)
d4-08
Frequency Reference Bias Upper Limit (Up/Down
2)
d4-09
Frequency Reference Bias Lower Limit (Up/Down
2)
d4-10 Up/Down Frequency Reference Limit Selection
d6-01 Field Weakening Level
d6-02 Field Weakening Frequency Limit
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Maximum Output Frequency
E1-05 Maximum Voltage
E1-06 Base Frequency
E1-07 Middle Output Frequency
E1-08 Middle Output Frequency Voltage
E1-09 Minimum Output Frequency
E1-10 Minimum Output Frequency Voltage
E1-11 Middle Output Frequency 2
E1-12 Middle Output Frequency Voltage 2
E1-13 Base Voltage
E2-01 Motor Rated Current
E2-02 Motor Rated Slip
E2-03 Motor No-Load Current
E2-04 Number of Motor Poles
E2-05 Motor Line-to-Line Resistance
E2-06 Motor Leakage Inductance
E2-10 Motor Iron Loss for Torque Compensation
E2-11 Motor Rated Power
F4-01 Terminal V1 Monitor Selection
F4-02
Terminal V1 Monitor Gain
F4-03 Terminal V2 Monitor Selection
F4-04
Terminal V2 Monitor Gain
F4-05
Terminal V1 Monitor Bias
F4-06
Terminal V2 Monitor Bias
F4-07 Terminal V1 Signal Level
F4-08 Terminal V2 Signal Level
No. Name
User
Setting
F6-01 Communications Error Operation Selection
F6-02
External Fault from Comm. Option Detection
Selection
F6-03
External Fault from Comm. Option Operation
Selection
F6-04 bUS Error Detection Time
F6-07
Multi-Step Speed Enable/Disable Selection when
NefRef/ComRef is Selected
F6-08 Reset Communication Parameters
F6-10 CC-Link Node Address
F6-11 CC-Link Communications Speed
F6-14 CC-Link bUS Error Auto Reset
F6-20 MECHATROLINK Station Address
F6-21 MECHATROLINK Frame Size
F6-22 MECHATROLINK Link Speed
F6-23 MECHATROLINK Monitor Selection (E)
F6-24 MECHATROLINK Monitor Selection (F)
F6-25 Operation Selection at Watchdog Timer Error (E5)
F6-26 MECHATROLINK bUS Errors Detected
F6-30 PROFIBUS-DP Node Address
F6-31 PROFIBUS-DP Clear Mode Selection
F6-32 PROFIBUS-DP Data Format Selection
F6-35 CANopen Node ID Selection
F6-36 CANopen Communication Speed
F6-50 DeviceNet MAC Address
F6-51 DeviceNet Communication Speed
F6-52 DeviceNet PCA Setting
F6-53 DeviceNet PPA Setting
F6-54 DeviceNet Idle Mode Fault Detection
F6-55 DeviceNet Baud Rate Monitor
F6-56 DeviceNet Speed Scaling
F6-57 DeviceNet Current Scaling
F6-58 DeviceNet Torque Scaling
F6-59 DeviceNet Power Scaling
F6-60 DeviceNet Voltage Scaling
F6-61 DeviceNet Time Scaling
F6-62 DeviceNet Heartbeat Interval
F6-63 DeviceNet Network MAC ID
H1-01
Multi-Function Digital Input Terminal S1 Function
Selection
H1-02
Multi-Function Digital Input Terminal S2 Function
Selection
H1-03
Multi-Function Digital Input Terminal S3 Function
Selection
H1-04
Multi-Function Digital Input Terminal S4 Function
Selection
H1-05
Multi-Function Digital Input Terminal S5 Function
Selection
H1-06
Multi-Function Digital Input Terminal S6 Function
Selection
H1-07
Multi-Function Digital Input Terminal S7 Function
Selection
E.3 User Setting Table
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
575