R Series Service Manual
9650-0903-01 Rev. L 5-5
Accessories
R Series accessories include the following:
All legacy M Series accessories (paddles, padz, internal handles, SpO
2
, 3/5Lead ECG, NIBP cuffs, etc.)
EtCO
2
Capnostat 5 sensor.
R Series unicables and R Series electrodes. The fully featured models support defib, pace, CPR, date code, condition sensor, defib self-test while pre-
connected, and monitoring while pacing.
Sync in/Sync out cable (Not sold by ZOLL - third party makes this cable).
USB cable (Not sold by ZOLL - compatible with standard USB cables).
Printer paper.
Power Management Support Functions
Charger Functions
When battery is fully charged, the charge current is terminated by setting the charger current PWM to less than 15%. The charger resumes supplying
battery current when the SOC reaches 95% +/-1%.
R Series powers on when a battery is dropped-in if the loaded battery Voltage is above the hardware threshold (8.7V). Upon battery drop-in, charger
current-limit is established on the basis of Battery conditions and DC bus Voltage. If the battery charge was recently terminated due to over-current, the
charger FET is opened, and the replace battery is indicated.
Shut-down Functions
The software initiates the shutdown sequence (“replace battery”) when the Kelvin Battery A/D Voltage is 9.3V or at 600mA-hrs of remaining capacity,
whichever occurs first. (Remaining capacity is read from the battery as a 16-bit unsigned quantity directly in mA-hrs).
The hardware will not shutdown if the input Voltage (at the switched-power node) is above 8.7V.
The software initiates “low battery” at an RTTE (run-time-to-empty) of 65 minutes. This is designed to allow 25 minutes of run-time until "replace
battery" under nominal R Series operating conditions in monitor mode with no printer.
If the system shuts down due a slowly depleting battery, the R Series system requires user-intervention to turn back on. This could be due to battery drop-
in or the front panel switch.

Table of Contents

Other manuals for ZOLL R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZOLL R Series and is the answer not in the manual?

ZOLL R Series Specifications

General IconGeneral
Defibrillator TypeManual and AED
PacingYes
ECG MonitoringYes
SpO2 MonitoringYes
FAST-SpO2Yes
IP RatingIP55
Defibrillator WaveformBiphasic
Energy Levels1-360 Joules
DisplayLCD
Pacer TypeDemand
Pacer Rate30-180 ppm
Pacer Output0 – 140 mA
EtCO2 MonitoringOptional
NIBP MonitoringOptional
Temperature MonitoringOptional
PrinterIntegrated
Battery TypeLithium-ion
CPR FeedbackYes
Data StorageInternal memory
ConnectivityUSB

Related product manuals