ZXR10 2920/2928/2952
(V1.0) Access Switch User Manual Volume I
236 Confidential and Proprietary Information of ZTE CORPORATION
f etherStatsDataSource: It is the same as that of the
history group. When configuring the data source
through the command line, enter the port number
directly.
f etherStatsOwner
f etherStatsStatus: It can be “valid”, “underCreation”,
“createRequest” and “invalid”. When it is set to
“invalid”, the instance is deleted. Control status can be
set to “valid” only when data source is specified.
4. To create/configure instances of the event group, use
command set event <1-65535> {description
<string>|type {none|log|snmptrap| logandtrap} |
owner <string>|community <string>| status
{valid|underCreation| createRequest|invalid}} in
SNMP config mode. This is shown in
Table 389.
TABLE 389 SET EVENT COMMAND
Format Mode Function
set event <1-65535>
{description
<string>|type
{none|log|snmptrap|
logandtrap} | owner
<string>|community
<string>| status
{valid|underCreation|
createRequest|invalid}}
SNMP config These
create/configure
instances of the
event group
Result: These create/configure instances of the event group.
Command line configuration of event group is to configure
eventTable in event group. The configuration involves:
f eventDescription.
f eventType: It can be “none(1)”, “log(2)”, “snmp-
trap(3)” and “log-and-trap(4)”. When the “log” is
selected, a log instance is created for each event in the
logTable. When the “snmp-trap” is selected, for each
event, the monitor sends an SNMP trap to one or more
management stations. When the “log-and-trap” is
selected, the log is created and a trap is sent.
f eventOwner.
f eventCommunity.
f eventStatus: It can be “valid”, “underCreation”,
“createRequest” and “invalid”. When it is set to
“invalid”, event instance is deleted.
5. To create/configure instances of the alarm group, use
command set alarm <1-65535> {interval <1-
65535>|variable <mib-oid>|sampletype
{absolute|delta}|startup
{rising|falling|both}|threshold <1-65535> eventindex

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2928 and is the answer not in the manual?

Zte ZXR10 2928 Specifications

General IconGeneral
MAC Address Table Size16K
VLAN4K
Jumbo Frame9K
Power SupplyAC 100-240V, 50/60Hz
Power Consumption< 30W
Dimensions440mm x 200mm x 44mm
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Ports24 x 10/100/1000Base-T ports, 4 x GE SFP ports