EasyManua.ls Logo

ABB ACH580-01 - Recommended Maintenance Intervals after Start-Up

ABB ACH580-01
398 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Recommended maintenance intervals after start-up
DescriptionAction
Quality of supply voltageP
Spare partsI
Capacitor reforming for spare modules and spare capacitors, see Capacit-
ors (page 227)
P
Tightness of terminalsI
Dustiness, corrosion or temperatureI
Heatsink cleaning, see Cleaning the heatsink (page 216)
I
Years from start-upComponent
21181512963
Cooling
Fans, IP21 (UL Type 1) frames R1 to R9
RRRMain cooling fan
R1…R4: page 218, R5: page 220
RRMain cooling fan LONGLIFE
R6…R8: page 220, R9; page221
RRRAuxiliary cooling fan for circuit boards
R4 v2 drive type 089A-4: page 225
RR
Auxiliary cooling fan (LONGLIFE) for circuit boards, R5: page 225 ,
R6…R9: page 222
Fans, IP55 (UL Type 12) frames R1 to R9
RRRMain cooling fan
R1…R4: page 218, R5: page 220
RRMain cooling fan LONGLIFE
R6…R8: page 220, R9; page 221
RRRRRRRAuxiliary cooling fan for circuit boards
R1…R2: page 223
RRRAuxiliary cooling fan for circuit boards
R4 v2: page 225
RRAuxiliary cooling fan (LONGLIFE) for circuit boards
R3: page 224, R4…R5: page 225 , R6…R9: page 222
RR
Second auxiliary cooling fan (LONGLIFE) R8 and R9: page 226
Aging
RR
Control panel battery: page 227
Functional safety
I
See the maintenance inform-
ation of the safety function.
Safety function test
20 years
Safety component expiry (Mission time, T
M
)
214 Maintenance

Table of Contents