Adjustable speed electrical power drive systems. Part 3: EMC re-
quirements and specific test methods
IEC/EN 61800-3:2017
Adjustable speed electrical power drive systems. Part 5-1: Safety
requirements – electrical, thermal and energy
IEC/EN 61800-5-1:2007
Adjustable speed electrical power drive systems. Part 9-2: Ecodesign
for power drive systems, motor starters, power electronics and their
driven applications – Energy efficiency indicators for power drive
systems and motor starters
IEC/EN 61800-9-2:2017
Insulation coordination for equipment within low-voltage systems.
Part 1: Principles, requirements and tests.
IEC 60664-1:2007
Standard for Safety, Adjustable Speed Electrical Power Drive Sys-
tems – Part 5-1: Safety Requirements – Electrical, Thermal and
Energy
UL 61800-5-1: 1st edition
Adjustable speed drives
CSA C22.2 No. 274-17
Note: US variants 343A-2 and 396A-2 have not been verified to comply with CSA, CE
or IEC directives or any standard other than UL 61800-5-1: 1st edition.
Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment. All printed circuit boards are conformal coated.
Transportation
in the package
Storage
in the package
Operation
installed for
stationary use
--• 0…4000 m
(13123 ft) above
sea level
1)
• 0…2000 m (6561
ft) above sea
level
2)
Output derated
above 1000 m (3281
ft), see section Alti-
tude derat-
ing (page 245).
Installation site altitude
-40…+70 °C
(-40…+158 °F)
-40…+70 °C
(-40…+158 °F)
-15…+50 °C
(5…122 °F).
0…-15 °C
(32…5 °F): No frost
allowed. See section
Ratings (page 231).
Air temperature
Max. 95%Max. 95%5…95%Relative humidity
No condensation allowed. Maximum allowed relative humidity is
60% in the presence of corrosive gases.
300 Technical data