Brake resistor connection data for frames R1…R3
The brake resistor output is conditionally short-circuit proof by
IEC/EN 61800-5-1. Rated conditional short-circuit current as
defined in IEC 61439-1.
Short-circuit protection
(IEC/EN 61800-5-1, IEC 61439-
1)
Control connection data
Maximum power:
Frames R1…R5: 25 W, 1.04 A at 24 V AC/DC ±10% with an
option module
Frames R6…R9: 36 W, 1.50 A at 24 V AC/DC ±10% as stand-
ard
External power supply
Supplied from an external power supply through option module
CMOD-01 or CMOD-02 with frames R1…R5. With frames
R6…R9 no options are needed.
Terminal size:
Frames R1…R5: 0.2…2.5 mm
2
(24...14 AWG)
Frames R6…R9: 0.14…2.5 mm
2
(26...14 AWG)
Total load capacity of this outputs is 6.0 W (250 mA / 24 V)
minus the power taken by the option modules installed on the
board.
+24 V DC output
(Term. 10)
Terminal size:
Frames R1…R5: 0.2…2.5 mm
2
(24...14 AWG)
Frames R6…R9: 0.14…2.5 mm
2
(26...14 AWG)
Technical data 291