Examining the installation site
The drive must be installed on the wall or an enclosure. There are three alternative ways
to install it:
• Vertical
Note: Do not install the drive upside down.
Vertical installation - Free spaceFrame
size
IP55 (UL Type 12)IP21 (UL Type 1)
Beside (c)
3)
Below (b)
2)
Above (a)
1)
Beside (c)
3)
Below (b)
2)
Above (a)
1)
inmminmminmminmminmminmm
5.911504.571165.391375.911503.39865.91150R1
5.911504.571165.391375.911503.39865.91150R2
5.911502.09537.872005.911502.09537.87200R3
5.911507.872002.09535.911507.872002.0953R4
5.911507.872003.941005.911507.872003.94100R5
5.9115011.813006.101555.9115011.813006.10155R6
5.9115011.813006.101555.9115011.813006.10155R7
5.9115011.813006.101555.9115011.813006.10155R8
5.9115011.813007.872005.9115011.813007.87200R9
1)
Free space above is measured from the frame, not from the hood used in
UL Type 12 frames.
Note: The height of the hood for frames R4 and R9 exceeds the requirement of
free space above for these frames
54 Mechanical installation