Horizontal, IP20 and IP55, R1…R5 only
Note 1: You can install IP21/UL Type 1 drives horizontally but the installation meets
IP20 requirements only.
Note 2: IP55/UL Type 12 drives mounted horizontally meets IP21/UL Type 1 ratings.
Note 3: In the horizontal mounting, the drive is not protected from dripping water.
Note 4: The vibration specification in Ambient conditions (page 300) may not be
fulfilled.
d
c
d
c
a
b
b
a
Horizontal installation - Free spaceFrame
size
IP55 (UL Type 12)IP21 (IP20)
Below (b)
1)
Above (a)Below (b)
1)
Above (a)
inmminmminmminmm
4.571165.391373.39865.91150R1
4.571165.391373.39865.91150R2
2.09537.872002.09537.87200R3
7.872001.18307.872001.1830R4
7.872001.18307.872001.1830R5
Side down (d)Side up (c)Side down (d)Side up (c)Frame
size
inmminmminmminmm
7.872001.18307.872001.1830R1
7.872001.18307.872001.1830R2
7.872001.18307.872001.1830R3
7.872001.18307.872001.1830R4
7.872001.18307.872001.1830R5
1)
Free space below is always measured from the drive frame, not from the cable
box.
58 Mechanical installation