Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
3
1.6 Output frequency (page 136).
Output frequency
4
1.7 Motor current (page 136).
Motor current
6
1.10 Motor torque (page 136).
Motor torque
7
1.11 DC voltage (page 136).
DC voltage
8
1.14 Output power (page 137).
Power inu out
10
23.1 Speed ref ramp input (page 271).
Speed ref ramp in
11
23.2 Speed ref ramp output (page 271).
Speed ref ramped
12
24.1 Used speed reference (page 278).
Speed ref used
13
26.2 Torque reference used (page 296).
Torq ref used
14
28.2 Frequency ref ramp output (page 305).
Freq ref used
16
40.1 Process PID output actual (page 375).
Process PID out
17
40.2 Process PID feedback actual (page 375).
Process PID fbk
18
40.3 Process PID setpoint actual (page 375).
Process PID act
19
40.4 Process PID deviation actual (page 375).
Process PID dev
See Terms and abbreviations (page 132).
Other
20
1.70 Ambient temperature % (page 139).
The amplitude range of 0…100% corresponds to 0…60 °C
or 32…140 °F.
Ambient temperature
100.00 / real32Defines the signal value that corresponds to 100%
amplitude.
AL2 signal scaling36.7
1 = 1 / 100 = 1Signal value corresponding to 100%.0.00 ... 32767.00
- / uint16Determines whether amplitude loggers 1 and 2 are active
continuously or only when the drive is modulating.
Logger function36.8
0 = Amplitude logger 1 active continuously
1 = Amplitude logger 1 active only when the drive is
modulating
AL1b0
0 = Amplitude logger 2 active continuously
1 = Amplitude logger 2 active only when the drive is
modulating
AL2b1
Reservedb2…15
1 = 10000h…FFFFh
Done / uint16Resets the peak value logger and/or amplitude logger 2.
(Amplitude logger 1 cannot be reset.)
Reset loggers36.9
0Reset completed or not requested (normal operation).Done
1Reset both the peak value logger and amplitude logger 2.All
2Reset the peak value logger.PVL
3Reset amplitude logger 2.AL2
- / real32Displays the peak value recorded by the peak value logger.PVL peak value36.10
1 = 1 / 100 = 1Peak value.-32768.00 ...
32767.00