Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Parameter values for process PID control.Process PID set 140
The drive contains a single active PID controller for process
use, however two separate complete set-ups can be
programmed and stored.
The first set is made up of parameters 40.07…40.56*, the
second set is defined by the parameters in group 41
Process PID set 2. The binary source that defines which
set is used is selected by parameter 40.57 PID set1/set2
selection.
See section Process PID control (page 72), and the control
chain diagrams on pages 640 and 641.
*The remaining parameters in this group are common for
both sets.
- / real32Displays the output of the process PID controller. See the
control chain diagram on page 641.
Process PID output
actual
40.1
This parameter is read-only. The unit is selected by
parameter 40.12 Set 1 unit selection.
1 = 1 / 10 = 1Process PID controller output.-32768.0 ... 32767.0
- / real32Displays the value of process feedback after source
selection, mathematical function (parameter 40.10 Set 1
Process PID feedback
actual
40.2
feedback function), and filtering. See the control chain
diagram on page 640.
This parameter is read-only. The unit is selected by
parameter 40.12 Set 1 unit selection.
1 = 1 / 100 = 1Process feedback.-32768.00 ...
32767.00
- / real32Displays the value of process PID setpoint after source
selection, mathematical function (40.18 Set 1 setpoint
Process PID setpoint
actual
40.3
function), limitation and ramping. See the control chain
diagram on page 641.
This parameter is read-only. The unit is selected by
parameter 40.12 Set 1 unit selection.
1 = 1 / 100 = 1Setpoint for process PID controller.-32768.00 ...
32767.00
- / real32Displays the process PID deviation. By default, this value
equals setpoint - feedback, but deviation can be inverted
Process PID deviation
actual
40.4
by parameter 40.31 Set 1 deviation inversion. See the
control chain diagram on page 641.
This parameter is read-only. The unit is selected by
parameter 40.12 Set 1 unit selection.
1 = 1 / 100 = 1PID deviation.-32768.00 ...
32767.00
- / real32Displays the trimmed reference output. See the control
chain diagram on page 641.
Process PID trim
output act
40.5
This parameter is read-only. The unit is selected by
parameter 40.12 Set 1 unit selection.
1 = 1 / 1 = 1Trimmed reference.-32768...32767
- / uint16Displays status information on process PID control.
This parameter is read-only.
Process PID status
word
40.6
1 = Process PID control active.PID activeb0
Parameters 375