10.2 DI delayed status, bit 4
Reserved10037
10.2 DI delayed status, bit 5
Reserved10038
10.2 DI delayed status, bit 6
Reserved10039
10.2 DI delayed status, bit 7
Reserved10040
10.2 DI delayed status, bit 8
Reserved10041
10.2 DI delayed status, bit 9
Reserved10042
10.2 DI delayed status, bit 10
Reserved10043
10.2 DI delayed status, bit 11
Reserved10044
10.2 DI delayed status, bit 12
Reserved10045
10.2 DI delayed status, bit 13
Reserved10046
10.2 DI delayed status, bit 14
Reserved10047
10.2 DI delayed status, bit 15
Reserved10048
Error code registers (holding registers 400090…400100)
These registers contain information about the last query. The error register is cleared
when a query has finished successfully.
DescriptionNameReference
1 = Reset internal error registers (91…95).Reset Error Registers90
Function code of the failed query.Error Function Code91
Set when exception code 04h is generated (see table
above).
Error Code92
00h No error
02h Low/High limit exceeded
03h Faulty Index: Unavailable index of an array
parameter
05h Incorrect Data Type: Value does not match
the data type of the parameter
65h General Error: Undefined error when handling
query
The last register (discrete input, coil, or holding re-
gister) that failed to be read or written.
Failed Register93
The last register that was written successfully.Last Register Written Suc-
cessfully
94
The last register that was read successfully.Last Register Read Success-
fully
95
608 Fieldbus control through the embedded fieldbus interface (EFB)