Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1Reversed rotation direction.U W V
0.000 mH / real32Defines the inductance of a custom sine filter, i.e. when
parameter 95.15 Special HW settings bit 3 is activated.
Note: For an ABB sine filter (95.15 Special HW settings
bit 1), this parameter is set automatically and should not
be adjusted.
Sine filter inductance99.18
1000 = 1 mH / 1000 =
1 mH
Inductance of custom sine filter.0.000 ... 100000.000
mH
0.00 uF / real32Defines the capacitance of a custom sine filter, i.e. when
parameter 95.15 Special HW settings bit 3 is activated.
If the capacitors are star/wye-connected, enter the
capacitance of one leg into the parameter.
If the capacitors are delta-connected, multiply the
capacitance of one leg by 3 and enter the result into the
parameter.
Note: For an ABB sine filter (95.15 Special HW settings
bit 1), this parameter is set automatically and should not
be adjusted.
Sine filter capacitance99.19
100 = 1 uF / 100 = 1
uF
Capacitance of custom sine filter.0.00 ... 100000.00 uF
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
FSO-xx settings.
This group contains parameters related to the optional
FSO-xx safety functions module. For details, refer to the
documentation of the FSO-xx module.
Safety200
Parameters 535