Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / real32Estimated motor current in A when a step-up transformer
is in use. The value is calculated from parameter 1.7 using
the step-up transformer ratio (95.40) and sine filter values
99.18 and 99.19.
Step-up motor current1.71
- / -
Estimated motor current. For scaling, see parameter 46.5.
0.00 ... 30000.00 A
- / real32U-phase rms current.U-phase RMS current1.72
- / -
U-phase rms current. For scaling, see parameter 46.5.
0.00 ... 30000.00 A
- / real32V-phase rms current.V-phase RMS current1.73
- / -
V-phase rms current. For scaling, see parameter 46.5.
0.00 ... 30000.00 A
- / real32W-phase rms current.W-phase RMS current1.74
- / -
W-phase rms current. For scaling, see parameter 46.5.
0.00 ... 30000.00 A
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated line current flowing through the supply unit.
Line current1.102
- / -
Estimated line current. For scaling, see parameter 46.5.
0.00 ... 30000.00 A
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated active current flowing through the supply unit.
Active current1.104
- / -
Estimated active current. For scaling, see parameter 46.5.
-30000.00 ...
30000.00 A
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated reactive current flowing through the supply unit.
Reactive current1.106
- / -Estimated reactive current. For scaling, see parameter
46.5.
-30000.00 ...
30000.00 A
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated frequency of the power supply network.
Grid frequency1.108
- / -Estimated supply frequency. For scaling, see parameter
46.2.
0.00 ... 100.00 Hz
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated voltage of the power supply network.
Grid voltage1.109
10 = 1 V / 100 = 1 VEstimated supply voltage.0.00 ... 2000.00 V
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated apparent power being transferred through the
supply unit.
Grid apparent power1.110
- / -Estimated apparent power. For scaling, see parameter
46.4.
-30000.00 ...
30000.00 kVA
- / real32
(Only visible when IGBT supply unit control activated by
95.20)
Estimated power being transferred through the supply unit.
Grid power1.112
- / -
Estimated supply power. For scaling, see parameter 46.4.
-30000.00 ...
30000.00 kW
140 Parameters