Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Fieldbus adapter A configuration.FBA A settings51
- / uint16Displays the type of the connected fieldbus adapter module.
0 = Module is not found or is not properly connected, or is
disabled by parameter 50.1 FBA A enable; 1 = FPBA; 32
FBA A type51.1
= FCAN; 37 = FDNA; 101 = FCNA, 128 = FENA-11/21;
135 = FECA; 136 = FEPL; 485 = FSCA.
This parameter is read-only.
- / uint16
Parameters 51.0251.26 are adapter module-specific.
For more information, see the documentation of the fieldbus
FBA A Par251.2
adapter module. Note that not all of these parameters are
necessarily in use.
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0...65535
- / uint16
See parameter 51.2 FBA A Par2.
FBA A Par2651.26
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0...65535
Done / uint16Validates any changed fieldbus adapter module
configuration settings. After refreshing, the value reverts
automatically to Done.
FBA A par refresh51.27
Note: This parameter cannot be changed while the drive
is running.
0Refreshing done.Done
1Refreshing.Refresh
0 / uint16Displays the parameter table revision of the fieldbus
adapter module mapping file (stored in the memory of the
drive).
FBA A par table ver51.28
In format axyz, where ax = major table revision number;
yz = minor table revision number.
This parameter is read-only.
1 = 1Parameter table revision of adapter module.0000…FFFFh
- / uint16Displays the drive type code in the fieldbus adapter module
mapping file (stored in the memory of the drive).
FBA A drive type
code
51.29
This parameter is read-only.
- / uint16Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
FBA A mapping file
ver
51.30
This parameter is read-only.
- / uint16Displays the status of the fieldbus adapter module
communication.
D2FBA A comm
status
51.31
0Adapter is not configured.Not configured
1Adapter is initializing.Initializing
2A timeout has occurred in the communication between the
adapter and the drive.
Time out
3Adapter configuration error: mapping file not found in the
file system of the drive, or mapping file upload has failed
more than three times.
Configuration error
4Fieldbus communication is off-line.Off-line
424 Parameters