EasyManua.ls Logo

ABB ACS880 - FBA B Settings

ABB ACS880
646 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Fieldbus adapter B configuration.FBA B settings54
- / uint16Displays the type of the connected fieldbus adapter module.
0 = Module is not found or is not properly connected, or is
FBA B type54.1
disabled by parameter 50.31 FBA B enable; 1 = FPBA; 32
= FCAN; 37 = FDNA; 101 = FCNA, 128 = FENA-11/21;
135 = FECA; 136 = FEPL; 485 = FSCA.
This parameter is read-only.
- / uint16
Parameters 54.0254.26 are adapter module-specific.
For more information, see the documentation of the fieldbus
FBA B Par254.2
adapter module. Note that not all of these parameters are
necessarily in use.
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0.0 ... 65535.0
- / uint16
See parameter 54.2 FBA B Par2.
FBA B Par2654.26
1 = 1 / 1 = 1Fieldbus adapter configuration parameter.0.0 ... 65535.0
Done / uint16Validates any changed fieldbus adapter module
configuration settings. After refreshing, the value reverts
automatically to Done.
FBA B par refresh54.27
Note: This parameter cannot be changed while the drive
is running.
0Refreshing done.Done
1Refreshing.Refresh
0 / uint16Displays the parameter table revision of the fieldbus
adapter module mapping file (stored in the memory of the
FBA B par table ver54.28
drive). In format axyz, where ax = major table revision
number; yz = minor table revision number.
This parameter is read-only.
1 = 1Parameter table revision of adapter module.0000…FFFFh
- / uint16Displays the drive type code in the fieldbus adapter module
mapping file (stored in the memory of the drive).
FBA B drive type
code
54.29
This parameter is read-only.
1 = 1 / 1 = 1Drive type code stored in the mapping file.0...65535
- / uint16Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
FBA B mapping file
ver
54.30
This parameter is read-only.
1 = 1 / 1 = 1Mapping file revision.0...65535
- / uint16Displays the status of the fieldbus adapter module
communication.
D2FBA B comm
status
54.31
0Adapter is not configured.Not configured
1Adapter is initializing.Initializing
2A timeout has occurred in the communication between the
adapter and the drive.
Time out
3Adapter configuration error: mapping file not found in the
file system of the drive, or mapping file upload has failed
more than three times.
Configuration error
428 Parameters

Table of Contents

Other manuals for ABB ACS880

Related product manuals