Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Selection of data to be transferred from fieldbus controller
to drive through fieldbus adapter A.
Note: 32-bit values require two consecutive parameters.
Whenever a 32-bit value is selected in a data parameter,
the next parameter is automatically reserved.
FBA A data out53
None / uint32
Parameters 53.0153.12 select data to be transferred
from the fieldbus controller to the drive through fieldbus
adapter A.
FBA data out153.1
0None.None
1Control Word (16 bits)CW 16bit
2Reference REF1 (16 bits)Ref1 16bit
3Reference REF2 (16 bits)Ref2 16bit
11Control Word (32 bits)CW 32bit
12Reference REF1 (32 bits)Ref1 32bit
13Reference REF2 (32 bits)Ref2 32bit
21Control Word 2 (16 bits)CW2 16bit
See Terms and abbreviations (page 132).
Other
None / uint32
See parameter 53.1 FBA data out1.
FBA data out1253.12