Retention
363
1SVC 440 795 M1100
X Use the cursor buttons Í and Ú to move to the LIGHTING
menu.
X Press the OK button.
X Use cursor buttons Í and Ú to change the value in 25 %
steps.
X Set the required backlighting.
.
Retention It is a requirement of system and machine controllers for
operating states or actual values to have retentive settings.
What this means is that the values will be retained safely
even after the supply voltage to a machine or system has
been switched off and are also retained until the next time
the actual value is overwritten.
The following operands and function blocks can be set to
operate retentively:
•Markers
• Counter function blocks,
• Data function blocks and
• Timing relays.
CONTRAST: +1
LIGHTING 75 %
CONTRAST: +1
LIGHTING 75 %
h
The backlight will immediately change to the set value. 0,
25, 50, 75 and 100 % are possible values.
CONTRAST: +1
LIGHTING 100 %
h
The display system comes with the following factory
setting:
The contrast is set to 0.
The backlight is set to 75 %.