Wiring with the display system
122
1SVC 440 795 M1100
Usable relays and function blocks (coils)
The display system provides various relay types as well as
function blocks and their coils for wiring in a circuit diagram.
Relay/function block Display
system
display
Number Coil Parameter
Outputs
Display system output relay, network
station (only network master)
* = Station address 2 to 8
*Q 0108 j
output relay Q 0108 j
Display system output relay
expansion, network station (only
network master)
* = Station address 2 to 8
*S 0108 j
Display system output relay expansion
S 0108 j
Bit outputs
* = Station address 1 to 8
*SN 0132 j
General coils
Auxiliary relay (markers) M 0196 j
COM slave marker (REMOTE
MARKER)
1M 0196 j
Jump label : 0132 j
Function blocks
Analog value comparator function
block
A 0132 j
Arithmetic function block AR 0132 j
Data block comparator, activate BC X EN 01 32 j j
Transfer data block, trigger coil BT X T_ 01 32 j j
Boolean operation BV 0132 j
Counter function block, counter input C X C_ X=0132 j j
Counter function block, direction C X D_ X=0132 j j