Attribute Description
Door
Sounder
Door controller PCB mounted sounder sounds on door alarms.
Ignore
Forced
Door forced open is not processed.
Interlock*
(Browser)
Only one door in an area will be allowed open at a time. Requires Door Group.
Setting Prefix Authorisation with prefix (A,B,* or #) key to set system
* Require door group
Door timers
Timer Min. Max. Description
Access
granted
1 s 255 s The time the lock will remain open after granting access.
Access
deny
1 s 255 s The duration after which the controller will be ready to read the next event after a
invalid event.
Door open 1 s 255 s Duration within which the door must be closed to prevent a “door open too long”
alarm.
Door left
open
1 min 180
min
Duration within which the door must be closed to prevent a “door left open”
alarm.
Extended 1 s 255 s Additional time after granting access to a card with extended time attribute.
Escort 1 s 30 s Time period after presenting a card with escort attribute within a user without
escort right can access the door.
14.12 Outputs
Each zone type on the SPC system has an associated output type (an internal flag or indicator). When a
zone type is activated, that is, a door or window opens, smoke is detected, an alarm is detected, etc., the
corresponding output is activated.
1. Scroll to OUTPUTS and press SELECT.
2. Scroll to CONTROLLER or EXPANDER and press SELECT.
3. Scroll to the expander/output to be programmed and press SELECT.
If the output activations are recorded in the system event log (that is, enabled, items
recorded/disabled, items) the programming options are available as shown in the table below.
NAMES Used to help identify the output; enter a specific and descriptive name.
OUTPUT
TYPE
Determines the output type; see the table in Outputs types and output ports
on the facing page, for a description of output types.
OUTPUT
MODE
Determines the style of the output: continuous, momentary or pulsed.
POLARITY Determines whether the output is activated on a positive or negative polarity.
LOG Determines if system log is enabled or disabled.