To test a keypad:
1. Scroll to VISUAL IND.
2. Press SELECT.
3. Press ENABLE.
On the LCD keypad, two rows of continuously changing characters are displayed.
On the Comfort keypad, all the LED indicators are lit and all screen pixels are displayed.
1. Press BACK to disable the test.
2. Press BACK to exit.
14.14.8 Seismic Test
To perform a seismic test:
1. Scroll to TEST > SEISMIC TEST.
2. Press SELECT.
3. Select TEST ALL AREAS, or select an individual area to test.
4. If you select an individual area to test, you can select either TEST ALL ZONES or select a
specific seismic zone to test.
The message ‘SEISMIC TEST’ is display on the keypad while the test is being performed.
If the test fails, the message ‘SEISMIC FAIL’ is displayed. If the “i” or VIEW key is pressed, a
list of the failed zones is displayed which can be scrolled through.
If the test succeeds, ‘SEISMIC OK’ is displayed.
See also
Seismic Sensor Testing on page256.
14.15 Utilities
1. Scroll to UTILITIES and press SELECT.
2. Scroll to the desired programming option:
SYSTEM
SOFTWARE
To view the current software version.
DEFAULTS To reset users or return the system to factory setting.
BACKUP
CONFIG
To back-up a configuration.
RESTORE
CONFIG
To restore a configuration.
SYSTEM
RESTART
To restart the system.
LICENSE Enter a license number to change the SPC license key. The system
does not log or report a license change.
14.16 Isolate
Zones, system alerts or alerts from X-BUS devices can be manually isolated from the keypad.
Isolating a zone removes that zone from the system until the user de-isolates it.