Entry Time Output turns on at the end of Exit time and off at the beginning of Entry
time.
Fire Exit Output turns on if any fire exit zones are active.
Unset Output turns on if any user unsets system momentary
Alarm Reset Output turns on if an alarm is reset momentary.
Resetting
Alarm
Output turns on during a setting procedure if glass break/smoke open
and not in alarm.
Engineer Exit Output turns on when an engineer exits from Engineer mode
momentary.
Keypad Valid
PIN
Output turns on when valid user PIN entered on keypad and fire zone is
active
3. Select the behavior of the output.
On Output will remain on if auto set is active.
Keypad Output will follow keypad operation.
Progressive Output will give progressive warning of auto set.
Pulse Time Select the duration that the auto set output will remain active when
pulsed.
15.10.2 X-BUS
This section covers:
l
Expanders below
l
Keypads on page165
l
Door Controllers on page168
l
Cable Map on page168
l
Settings on page169
15.10.2.1 Expanders
1. Select Configuration > Hardware > X-Bus > Expanders.
For naming and identifying:
In loop configuration, each expander is numbered consecutively from the first
(expander connected to the 1A 1B on the controller) to the last (expander
connected to the 2A 2B on the controller).
Example for SPC63xx: Expanders, when numbered 1 through 63, are
allocated zones (in groupings of 8) in subsequent identities of 1 to 512 (the
greatest number in zone identification is 512). Therefore, any expander
named or identified by a number greater than 63 has no allocated zones.
2. Click one of the expander identifying parameters to display the Expander Configuration
page.
3. Configure the following fields:
Description For appearance on device LEDs.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser