The name of each exception displays in the Event Exceptions table at the bottom of the page.
The table shows the settings for the fields Report Event, Filter Exception, Event Code
(SIA/CID) and Remap Exception for the event.
4. Click the Edit icon to make changes or the Delete icon to remove an Event Exception.
5. To apply the event profile to an area, select the area checkbox.
6. Click Save to save the event profile.
7. Click Back to view the profile in the Event Profiles table.
15.11.2.7 Configuring Command Profiles
The command profile defines the commands that are allowed on an ATS. This profile determines how a
CMS can control a panel. The default command profile does not support video verification.
NOTICE: To quickly create a new command profile, go to Communications > FlexC > Command
Profiles. In the Command Profiles table, select a command profile and click the edit button (blue
pencil), Scroll to the bottom of the page and click Replicate. You can now make the changes you
require.
1. To add a command profile step by step, go to Communications > FlexC > Command Profiles.
2. Click Add.
3. Enter a Name to identify the command profile.
4. Select an Authentication Mode (Command User or Panel User, Command User Only, or Any
Panel User) from the dropdown menu.
NOTICE: The default Command User Name provides an out of the box user
that quickly and easily enables control of the panel from SPC Com XT. It
enables a broad range of commands. For example, the default command user
can set all areas or control all zones. For tighter control, for example to only
allow setting of certain areas, you can set up a customised command profile with
a defined set of rights. You cannot delete the Default Command Profile, the
Default Portal Command Profile or a command profile that is assigned to an
ATS.
5. Enter the name of the command profile user in the Command User Name field. This must match
the Authentication User Name field in SPC Com XT.
6. Enter the password of the command profile user in the Command Password field. This must
match the authentication User PIN or Password field in SPC Com XT.
7. Select the Live Streaming Mode (Disabled, Only after alarm event, Always available, System is
fullset) to determine the streaming privacy options. Always Available generates the highest
volume of data.
8. Under Command Filter, select the commands to enable. For a full list of commands, see FlexC
Commands on page289.
9. Select the commands to log.
10. Click Save.
11. Click Back to view the command profile in the Command Profiles table.
12. To change a command profile, click the Edit button next to a command profile.
15.11.3 Reporting
This section covers:
l
Alarm Reporting Centres (ARCs) on the facing page
l
EDP Setup on page238
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 235 I-200572