Using Code
Using Caller
ID
Action Response
****O5.ON
****.O5.ON
****.OUTPUT
Where output (mapping gate) is
identified as “O5”, it is triggered on.
Status of “O5”
For example:
l
Output O5 on.
l
Output heating on
(where heating is the
name of the output).
****O5.OFF
****.O5.OFF
Where output (mapping gate) is
identified as “O5”, it is triggered off.
Status of “O5”
For example: Output O5 off
****.CLR
****.RESTORE
Allows clear alerts by SMS.
For SMS recognition, output (mapping gate) identification uses the format ONNN, where O stands
for output, and NNN are the numeric placeholders, of which not all are necessary.
(Example: O5 for output 5)
For SMS recognition, X-10 device uses the format: XYNN, where X stands for X-10; Y stands for the
alphabetic identity and NN are the available numeric placeholders. (Example: XA1)
The SMS operates using a standard protocol that is used in SMS telephones. Note that some PSTN
operators do not provide the service of SMS over PSTN. For SMS to operate over PSTN, the following
criteria are required:
l
Caller ID needs to be enabled on the telephone line.
l
Direct telephone line not through PABX or other communications equipment.
l
Also note that most Service Providers only allow SMS to a telephone registered in the same
country. (This is due to billing issues.)
15.8.5 Deleting Web Passwords
This page lists the engineer and any user and Engineer password that has been created for accessing
the Web browser.
1. Select Users>Web Passwords.
2. Click the Delete button beside the Engineer or User to delete the password.
15.8.6 Configuring Engineer Settings
To configure engineer settings:
1. Select Users>Engineer.
2. Change the ’Engineer’ User Name if required.
3. Click the Change PIN button to change the Engineer PIN (see Changing Engineer PIN and web
password on the facing page).
Note: To comply with INCERT approvals, the user’s PIN code must contain more than 4 digits.
4. Select the Language that will be used by the engineer. (Only displayed if multiple languages
available see Upgrading Languages on page246.)
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 147 I-200572
08.12.2023